Brand Name: SIMO
Model Number: SIMO Blower 5-06
Certification: CE, ISO9001:2008,TUV
Place of Origin: Henan China
MOQ: 1 Set
Price: Negotiable
Payment Terms: T/T, L/C, Payment Term Is Negotiable
Supply Ability: 500 Sets Per Month
Delivery Time: 15-35 Days
Packaging Details: Export Wooden Case Packing, Steel pallet Packing
Voltage: 380V/415V/440V/660V/6KV/10KV
Power source: Three Phase AC Motor
After-sales Service Provided: Field installation, commissioning and training
Bearing: SKF/FAG/By your demand
Bearing cooling: Air cooling or Circulating Water cooling
System Type: Single inlet, Overhang type
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    Boiler Air Inlet 1989pa Centrifugal Extractor Fan Q235 Carbon Structural Steel

    Boiler Q235 Carbon Structural Steel Air Inlet Extractor Fan Centrifugal Blower


    Detail introduction :


    The 5-06 series fan can be used in the feeding system of 2-670t/h steam boiler in thermal power plants, it can also meet the requirements of the high-pressure head performance parameters of the fluidized bed furnace.

    This series of fans can also be used for dust removal, mine ventilation and general ventilation systems. The blower delivers air, and the induced draft fan delivers flue gas or gas containing foreign particles.

    It can be used for more than four years when the concentration of impurities is less than 200 mg/m3.

    If it contains a lot of impurities, it also can be used, but it will shorten the service life.

    The maximum operating temperature of the induced draft fan must not exceed 250°C.

    The performance of the fan is expressed by parameters such as fan flow, full pressure, spindle speed, shaft power and efficiency.


    Product features :


    1. Impeller:

    12 pieces of backward aerofoil blades are welded between the Arc cone front plate and the flat shaped rear plate. Because of the use of airfoil blades, the fan is guaranteed to have high efficiency, low noise and high strength. The impeller is corrected by static and dynamic balance, so the operation is stable. Forced draught fan and induced draught fan of the same machine number have same impeller structure.


    2. Casing:

    The casing is a volute welded by ordinary steel plates.

    The casing of a single suction fan is made in three different forms: The No. 8 to 12 casing is made into an integral structure and cannot be disassembled; The No. 14 to 16 casing is made into a two open structure; The No. 18~29.5 casing is made into a three open structure.

    The induced draft fan and the volute plate are appropriately thickened to prevent wear.


    3. Inlet:

    The converging and streamlined air inlet is made into a unitary structure and bolted to the inlet side of the fan.


    4. Adjustment door:

    A device for regulating the flow of the fan, axially mounted in front of the air inlet. The adjustment range is from 0° (full open) to 90°(fully closed).


    5. Transmission parts:

    The main shaft of the transmission part is made of high-quality steel, and the 5-51 series of fans are all made of roller bearings.

    The bearing housing is available in two forms: No. 8 ~ 16 uses a whole cylindrical bearing housing; No18 ~ 29.5 uses two independent pillow bearing boxes.

    The bearing housing is equipped with a thermometer and an oil level indicator (only the induced draft fan). The lubricating oil uses 46# mechanical oil, and the oil quantity is implemented according to the oil level mark. When the No8-16 integral cylindrical bearing housing uses dry oil, the oil retaining plate should be added to the ball side of the bearing housing, and the fixing grooves communicate with each other. The induced draft fan is equipped with a water cooling device, so a water supply pipe must be installed. Water consumption varies with temperature, and is generally considered to be 0.5 to 1 m3/h.


    Technical specifications:


    seriesmodelRotation Speed
    (r/min)
    Total Pressure
    (Pa)
    Air Capacity
    (m³/h)
    Power
    (kW)
    5-068D145025921989120282060715
    10D145040513108234934024955
    11D145030362329312695357155
    12.4D145038582960447927674090

    Provide the required centrifugal fan parameters, SIMO Blower can be customized according to requirements, the supply speed is fast, we will quote you in real time, the price is favorable!


    Product Advantages


    1. The impeller of centrifugal fan is designed to be backward inclined, which has no friction in operation, very low noise and is not easy to be stained with dust, so it is very convenient to maintain.

    2. Good ventilation effect: Centrifugal fan is especially suitable for pipe exhaust or air supply, and can be used in places where there is no corrosive, flammable and explosive gas, which can achieve good ventilation effect.

    3. Strong corrosion resistance: the surface of centrifugal fan is sprayed, which has strong oxidation resistance and is not easy to rust. The casing and impeller are made of high-quality steel plates, which makes the centrifugal fan very strong and durable.

    4. SIMO Blower uses high-quality raw materials, thick materials, or stainless steel plates,all formed at one time.


    FAQ


    1. What parameters need to be provided when you design the Heat Dissipation Power Plant Blower Fan?

    Answers: Air flow, total pressure or static pressure, inlet temperature, local voltage and frequency, Altitude etc.

    If there is flammable and explosive gas, or big dust loading in the medium, please also inform the designer.


    2. How about your company’s pre-sales service and after-sales service?

    Answers: Before our cooperation, we have the professional technical team to help you make the technical solution according to your working condition, to make sure the centrifugal fan efficiency operation.

    After sales service, we will offer 12 months’ repairing service, and provide lifelong follow-up services. Besides, our engineers are available for going abroad to offer the repairing service.


    3. Does your company have qualifications?

    Answers: SIMO Blower has obtained ISO 9001-2008, CE, BV certifications and so on.


    Quality Boiler Air Inlet 1989pa Centrifugal Extractor Fan Q235 Carbon Structural Steel for sale
    Send your message to this supplier
     
    *From:
    *To: Xinxiang SIMO Blower Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0

    Friendly Links: www.everychina.com

    Home| Products| Suppliers| Quality Suppliers| Site Map |About Us |Contact Us |Help |关于我们 |联系我们

    Copyright © 2009 - 2024 howtoaddlikebutton.com. All rights reserved.