Sign In | Join Free | My howtoaddlikebutton.com |
|
All zht4400 modbus relay output module wholesalers & zht4400 modbus relay output module manufacturers come from members. We doesn't provide zht4400 modbus relay output module products or service, please contact them directly and verify their companies info carefully.
Total 1745 products from zht4400 modbus relay output module Manufactures & Suppliers |
|
![]() |
Brand Name:GE Model Number:IC693MDL916 Place of Origin:USA ...Relay Output Modules IC693MDL930 Relay Output, Isolated, 4 Amp (8 Points) IC693MDL931 Relay Output, 8 Amp Form B/C contacts, Isolated in 2 Groups of 4 (8 Points) IC693MDL940 Relay Output, 2 Amp (16 Points) IC693MDL916 Relay Output, 4 Amp (16 Points) Mixed Discrete Modules IC693MDR390 Mixed I/O, 24 VDC Input (8 points), Relay Output (8 points) IC693MAR590 Mixed I/O, 120 VAC Input (8 Points), Relay Output... |
Shenzhen Wisdomlong Technology CO.,LTD
Guangdong |
![]() |
Brand Name:IOTROUTER Model Number:ET1010 Place of Origin:Sichuan, CHINA MODBUS RTU Protocol Industrial Remote IO Module with 4 Relay Input and 4 Relay Output Parameters of Remote IO Module RS485 Number of ports 1 way Operating mode Slave Support baud rate 115200/9600/4800/2400 DO Number of ports 4 way output type Relay output Relay... |
Chengdu Zongheng Intelligence Control Technology Co., Ltd.
Sichuan |
![]() |
Brand Name:CWT Model Number:CWT-MB Place of Origin:China ..., power supply, signal inputs and outputs, RS232 and RS485 interface(option Ethernet), interference protection designed to ensure data accuracy and reliability. RS485 communication interface performs MODBUS RTUprotocol, can be directly connected with the |
CWT(HK) Co., Limited
Guangdong |
![]() |
Brand Name:Lensen Model Number:LS-RDIO0404+LS-RDIO0202 Place of Origin:China LS-RDIO0202 wireless I/O module 2 digital inputs 2 relay output 2km wireless control Introduction LS-RDIO0202 Modbus RTU is a 1W I/O module, 2 isolated digital inputs, 2 isolated relay outputs, 1 RS485 (wireless RS485 customizes). Wireless control 2km-3km... |
Shenzhen Qianhai Lensen Technology Co., Ltd
Guangdong |
![]() |
Brand Name:Coolmay Model Number:CX3G-24MRT Place of Origin:China ...12DO Industrial Automation PLC Output Module Motor Driver Industrial PLC Logic Controller 12DI/12DO Modbus RTU Relay Tansistor Output Module Motor Driver - 12DI/12DO (6 relay/6 transistor) - Two rs485 port in plc support Modbus RTU - A default rs232 in PLC... |
Shenzhen Coolmay Technology Co., Ltd.
|
![]() |
Brand Name:Lensen Model Number:LS-RDIO1010 Place of Origin:China ...LS-RDIO0808+LS-RDIO2 expander, then each has 10DI 10DO Introduction LS-RDIO0808 Modbus RTU is a 1W I/O module, 8 isolated digital inputs, 8 isolated relay outputs, 1 RS485 (wireless RS485 customizes). Wireless control 2km-3km. Use for pump control, water... |
Shenzhen Qianhai Lensen Technology Co., Ltd
Guangdong |
![]() |
Brand Name:CWT Model Number:CWT5018 Place of Origin:China modbus remote io module, modbus tcp scada gateway System Feature Industrial NXP 32-bit ARM MCU Double watchdog to ensure stability With signal filtering mechanisms Network-reconnect and retransmission to ensure data accurately transmit Synchronize clock with multiple way, Sms, NTP, CwtIO Server Can set multiple timers(second, minute, day, week, month) to execute actions, e.g. output... |
CWT(HK) Co., Limited
Guangdong |
![]() |
Brand Name:IOTROUTER Model Number:ZHT0800 Place of Origin:Sichuan, CHINA ... 6 Operating Temperature -40℃~+65℃ Introduction of ZHT0800 ZHT0800 contains a 485 interface, multiple devices can be cascaded through the 485 bus. Each module can set the address, the |
Chengdu Zongheng Intelligence Control Technology Co., Ltd.
Sichuan |
![]() |
Brand Name:IOTROUTER Model Number:ZHT0800 Place of Origin:Sichuan, CHINA ... 6 Operating Temperature -40℃~+65℃ Introduction of ZHT0800 ZHT0800 contains a 485 interface, multiple devices can be cascaded through the 485 bus. Each module can set the address, the |
Chengdu Zongheng Intelligence Control Technology Co., Ltd.
Sichuan |
![]() |
Brand Name:AB Model Number:1746-OW16 Place of Origin:USA ... Frequency 50/60HZ Voltage 5-125VDC Point 16 Slc 500 Descriptions of 1746-OW16 The 1746-OW16 is an discrete output module used with SLC 500 product family. This module is a relay output module or sometimes referred as dry contact output module. This |
Shenzhen Viyork Technology Co., LTD
Guangdong |
![]() |
Brand Name:AB Model Number:1746-OW8 Place of Origin:USA ...Output Module Series A 5-265VAC 50/60Hz Quick Detials ALLEN BRADLEY 1746-OW8 1746OW8 RELAY OUTPUT MODULE SLC500 8 POINT 125 VDC 5-265 VAC 50/60 HZ one year warranty SPECIFICATIONS The 1746-OW8 is a SLC 500 Digital Contact Output Module. This Digital Contact Output Module has an Operating Voltage of 5-265 Volt AC or 5-125 Volts DC and 8 N.O. Relay Contact Outputs. It is intended for Relay Contact Outputs... |
Shenzhen Viyork Technology Co., LTD
Guangdong |
![]() |
Brand Name:GE Fanuc Model Number:IC693MDL930E Place of Origin:USA ...Relay Output Module The GE Fanuc IC693MDL930 is a 4 Amp Isolated Relay Output module. Designed for the Series 90-30 Programmable Logic Controller, this module provides 8 normally-open relay circuits. These enable the user to control output loads. Each circuit has a 4-amp output switching capacity. Each output point on the module... |
Guangzhou Sande Electric Co.,Ltd.
Hebei |
![]() |
Brand Name:CWT Model Number:CWT5018 Place of Origin:China ... for recording data in a line Modbus. The data logger is operating in stand-alone , can be connected to Master Modbus , or in the Modbus Slave , via a RS485 or RS232. The data acquired from the device can be transmit to web server by GPRS and Ethernet . |
CWT (HK) Co., Limited
Guangdong |
![]() |
Brand Name:CWT Model Number:CWT5018 Place of Origin:China ...Logger is used for recording data in a line Modbus. The data logger is operating in stand-alone , can be connected to Master Modbus , or in the Modbus Slave , via a RS485 or RS232. The data acquired from the device can be transmit to web server by GPRS and |
CWT (HK) Co., Limited
Guangdong |
![]() |
Brand Name:CWT Model Number:CWT5018 Place of Origin:China ...Modbus Control wind speed 4DI 8AI 2 Relay Output RS232 RS485 4-20mA Support 3G WCDMA /4G LTE Version (Skype: lisali1220, WhatsApp: 0086 13652426178) The CWT5018 GPRS Enthernet Modbus Data Logger is used for recording data in a line Modbus. The data logger is operating in stand-alone , can be connected to Master Modbus , or in the Modbus... |
CWT (HK) Co., Limited
Guangdong |
![]() |
Brand Name:CWT Model Number:CWT5018 Place of Origin:China ... monitor industry system remote alarm, control and data acquisition SCADA Cellular RTU, mobus RTU, GPRS 4G 3G modbus gateway,modbus RS485 RTU, modbus Ethernet RTU The CWT5018 GPRS Enthernet Modbus Data Logger is used for |
CWT (HK) Co., Limited
Guangdong |
![]() |
Brand Name:CWT Model Number:CWT5018 Place of Origin:China ... monitor industry system remote alarm, control and data acquisition SCADA Cellular RTU, mobus RTU, GPRS 4G 3G modbus gateway,modbus RS485 RTU, modbus Ethernet RTU The CWT5018 GPRS Enthernet Modbus Data Logger is used for |
CWT (HK) Co., Limited
Guangdong |
![]() |
Place of Origin:China Brand Name:CWT Model Number:CWT5002-2 ...Modbus RTU Master with Digital inputs and relay outputs Support 3G version ( skype: glare.wang) ( WhatsApp: 0086-13420971345) We Provide Free Web Cloud Software, Please contact us for more details CWT5002 is a Modbus RTU master device allowing read/write points of other Modbus... |
CWT(HK) Co., Limited
Guangdong |
![]() |
Brand Name:CWT Model Number:CWT5002-1 Place of Origin:China ...:00 86 13652426178 QQ : 2946370755 Product Details CWT5002-2 MODBUS GPRS Terminal enables various kinds of devices with I/O and AD and Standard MODBUS protocols to communicate over GSM/GPRS network and the Internet easily and freely. It can construct a |
CWT (HK) Co., Limited
Guangdong |